What size breaker do I need for a 50 gallon electric water heater?

What size breaker do I need for a 40 gallon electric water heater?

A 40-gallon water heater should have an average 4500 Watt capacity and 240 V emf. Thus, a 25 or 30A breaker is sufficient for a 40-gallon breaker. However, for your safety, we recommend getting a 30A breaker.Jul 3, 2021

Can I use a 40 amp breaker for a 30 amp water heater?

You just swap out a 30A breaker with a 40A breaker. You're allowing the electrical system (not just the breaker) to run at 33% over it's rated capacity.

What size breaker does a 4500 watt water heater take?

30-amp

How big of a breaker do I need for a water heater?

30-amp

Can I use a 40 amp breaker for water heater?

You cannot put a 40A breaker on #10 wire. If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

What size breaker is needed for a 50 gallon electric water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater.

What size breaker does an electric water heater need?

30-amp

Can I use a 40 amp breaker for a water heater?

You cannot put a 40A breaker on #10 wire. If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

Can a water heater run off a 20 amp breaker?

A water heater of this type is required to be considered a continuous load meaning that the branch circuit needs to be calculated at 125% of the heater's rated ampacityampacityAmpacity is defined as the maximum current, in amperes, that a conductor can carry continuously under the conditions of use without exceeding its temperature rating. Also described as current-carrying capacity.https://en.wikipedia.org › wiki › AmpacityAmpacity - Wikipedia. 4500/240 = 18.75 amps, will work on a 20 amp OCPD but, 18.75*125% = 23.4 amps, requires a 25 or 30 amp circuit.Oct 2, 2012