Teck cables with outer jacket may be used for exposed or concealed wiring in wet or dry locations, indoors/outdoors and in corrosive environments. Teck cables are suitable for use in ventilated, non-ventilated and ladder type cable troughs, in ventilated flexible cable ways in both dry and wet locations.
What is Teck 90 cable used for?
Copper Conductor Northern Cables Inc.'s TECK90 is an interlocked armoured cable for use in petro-chemical, pulp and paper, and other industrial application environments. TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations.
Can Teck cable be used outside?
Teck cables with outer jacket may be used for exposed or concealed wiring in wet or dry locations, indoors/outdoors and in corrosive environments. Teck cable with outer jacket is suitable for direct earth burial and for Class II Division 2, Class III, Divisions 1 and 2 hazardous locations per Canadian Electrical Code.
What is Teck cable called?
TECK90 Cable
What type of wire is in Teck cable?
copper conductors
What is HL Teck cable?
Teck 90-HL armoured and jacketed cables are suitable for exposed or concealed wiring in wet or dry locations where cables are subject to the risk of mechanical damage and chemical abuse. It can be used in ventilated or non-ventilated ladder type cable tray or troughs and for direct burial for Class I, Div 2 locations.
What is the difference between Type AC 90 and Type Teck 90 cable?
Type ACWU90 is used for feeders and service entrances, as well as certain dedicated branch circuits in non- combustible buildings. Types AC90, ACWU90 and TECK90 are acceptable for consumer service conductors, although Type AC90 is restricted to services above ground in dry locations.
Is Teck cable shielded?
CSA TECK 90 Armoured Power | Single Conductor Shielded (5000V) Shielded armoured power cable is used to supply power for lighting, drives, motors and pumps. Cable is suitable for use in outdoor exposed applications and is rated for damp or dry locations in -40°C (-40°F) environments.
How do I install Teck cable?
https://www.youtube.com/watch?v=fyECcFxJJnk
Can Teck cable be directly buried?
Teck cable with outer jacket is suitable for direct earth burial and for Class II Division 2, Class III, Divisions 1 and 2 hazardous locations per Canadian Electrical Code. Some of the features of Teck cable are its flexibility and ease of installation.
Can Teck 90 cable be buried?
Copper Conductor TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations.
Can Teck cable be installed in conduit?
"No you cannot run Teck cable in conduit, you have to stick to the Table 19 as indicated in article 12-100". The reason is that the heat dissipation for a Teck cable in a conduit is «unknown», so the ampacity cannot be determined.1 Apr 2015